Microplate Reader IMR-6000especially designed for QC function with 8-channel manifolds as standard accessories for use with standard 96 wells plates. Covers the absorbance range 0 to 4.000Abs with bandwidth 8 nm and measured quickly, which is significantly faster than other current microplate reader methods. End Point, fixed time, Kinetic make the IMR-6000 the best platform for any clinical, biotechnology research and pharmaceutical laboratory applications. Can stored more than 100 programs, up to 100,000 test records in a single unit. Maintain all important measuring parameters including ABS, Cut-Off, Single Standard, Curve, Multi-Percent, Percent Log, Linear, Exponential, Power, and 4PL Regression. A multi-mode reader has several benefits for laboratories applications ranging from ELISAs to nucleic acid and protein quantitation to cell imaging. Together with multiple microplate services and detection modes into a single, more versatile unit may be an ideal choice especially if you have limited area and performed 12 assays in a single plate.
Data sheet
Model  | IMR-6000  | |
Absorbance Range  | 0 to 4.000Abs  | |
Test Performance  | 12 different test in single plate  | |
Optical Path  | 8-channel  | |
Measurement Range  | 0.000-2.500Abs  | |
Accuracy  | ±0.1% or ±0.005Abs  | |
Resolution  | 0.001Abs ( displayed ) , 0.0001Abs (calculated)  | |
Light Source  | Halogen Iamp  | |
Band width  | 8 nm  | |
Optical filter  | 405nm, 450nm, 492nm, 630nm, (4 other filters optional)  | |
Wavelength Accuracy  | ±1nm  | |
Function  | QC function: Grubs, Westguard Multi-rule, Levey jennings plot (optional)  | |
Reading Speed  | 5 seconds for 96-well plate ( single wavelength )  | |
Printer  | Internal thermal printer , external printer optional  | |
Shaking  | Shaking time and speed adjustable  | |
Display  | LCD  | |
Applications  | ABS, %ABS, Cut-Off, Single Standard, Curve, Multi-Percent, Percent Log, Linear,Exponential, Power, 4PL Regression  | |
Storage  | More than 100 programs, up to 100,000 test results  | |
Interface  | RS-232, USB, SD card interface  | |
Dimensions  | 460x330 x200 mm  | |
Weight  | 9 kg  | |
Electrical Requirement  | AC100/50 Hz, ± 10%  | 220V/60Hz, ± 10%  | 
Catalogue No.  | 420350501  | 420350502  | 
|   Model  |    IMR-6000  |  |
|   Absorbance Range  |    0 to 4.000Abs  |  |
|   Test Performance  |    12 different test in single plate  |  |
|   Optical Path  |    8-channel  |  |
|   Measurement Range  |    0.000-2.500Abs  |  |
|   Accuracy  |    ±0.1% or ±0.005Abs  |  |
|   Resolution  |    0.001Abs ( displayed ) , 0.0001Abs (calculated)  |  |
|   Light Source  |    Halogen Iamp  |  |
|   Band width  |    8 nm  |  |
|   Optical filter  |    405nm, 450nm, 492nm, 630nm, (4 other filters optional)  |  |
|   Wavelength Accuracy  |    ±1nm  |  |
|   Function  |    QC function: Grubs, Westguard Multi-rule, Levey jennings plot (optional)  |  |
|   Reading Speed  |    5 seconds for 96-well plate ( single wavelength )  |  |
|   Printer  |    Internal thermal printer , external printer optional  |  |
|   Shaking  |    Shaking time and speed adjustable  |  |
|   Display  |    LCD  |  |
|   Applications  |    ABS, %ABS, Cut-Off, Single Standard, Curve, Multi-Percent, Percent Log, Linear,Exponential, Power, 4PL Regression  |  |
|   Storage  |    More than 100 programs, up to 100,000 test results  |  |
|   Interface  |    RS-232, USB, SD card interface  |  |
|   Dimensions  |    460x330 x200 mm  |  |
|   Weight  |    9 kg  |  |
|   Electrical Requirement  |    AC100/50 Hz, ± 10%  |    220V/60Hz, ± 10%  |  
|   Catalogue No.  |    420350501  |    420350502  |