Microplate Reader IMR-8000 provides benefit of a wider range of detection with 8-channel manifolds as standard accessories for use with standard 96 wells plates. Covers the full UV wavelength340 nm and absorbance range 0 to 4.000Abs with bandwidth <8 nm and measured quickly, which is significantly faster than other current microplate reader methods. End Point, fixed time, Kinetic make the IMR-8000 the best platform for any clinical, biotechnology research and pharmaceutical laboratory applications. Can stored more than 500 programs, up to 100,000test records in a single unit. Maintain all important measuring parameters including ABS, Cut-Off, Single Standard, Curve, Multi-Percent, Percent Log, Linear, Exponential, Power, and 4PL Regression. A multi-mode reader has several benefits for laboratories applications ranging from ELISAs to nucleic acid and protein quantitation to cell imaging. Together with multiple microplate services and detection modes into a single, more versatile unit may be an ideal choice especially if you have limited area and performed 12 assays in a single plate
Data sheet
Model  | IMR-8000  | |
Wavelength  | UV wavelength: 340 nm  | |
Absorbance Range  | 0 to 4000 Abs  | |
Test Performance  | 12 different  | |
Optical Path  | 8-channel  | |
Wavelength Accuracy  | ±1 nm  | |
Resolution  | 0.001 Abs (display), 0.0001 Abs (calculated) 
  | |
Light Source  | Halogen lamp 
  | |
Band width  | <8 nm  | |
Optical filter  | 340,405,450,492,630nm,(3 filters optional) 
  | |
Function  | End point, fixed time, Kinetic 
  | |
Reading Speed  | 5 Seconds for 96 well plate (single wavelength) 
  | |
Shaking  | Shaking time and speed adjustable 
  | |
Printer  | All printers compatible with windows 
  | |
Plate Incubation  | AT+4 to 45°C, adjustable 
  | |
Applications  | ABS, cut-off, single standard, curve, multi-percent, percent log, linear, exponential, power, 4PL regression 
  | |
Certification  | 
  | |
Storage  | More than 500 programs, up to 100,000 test result 
  | |
Interface  | 
 RS-232  | |
Dimensions  | 186x440x220 mm 
  | |
Weight  | 9 Kg 
  | |
Electrical Requirement  | AC 110V/50 Hz, ±10%, 
  | 240V/60 ±1Hz  | 
Catalogue No.  | 420450501  | 420450502  | 
|   Model  |    IMR-8000  |  |
|   Wavelength  |    UV wavelength: 340 nm  |  |
|   Absorbance Range  |    0 to 4000 Abs  |  |
|   Test Performance  |    12 different  |  |
|   Optical Path  |    8-channel  |  |
|   Wavelength Accuracy  |    ±1 nm  |  |
|   Resolution  |    0.001 Abs (display), 0.0001 Abs (calculated) 
  |  |
|   Light Source  |    Halogen lamp 
  |  |
|   Band width  |    <8 nm  |  |
|   Optical filter  |    340,405,450,492,630nm,(3 filters optional) 
  |  |
|   Function  |    End point, fixed time, Kinetic 
  |  |
|   Reading Speed  |    5 Seconds for 96 well plate (single wavelength) 
  |  |
|   Shaking  |    Shaking time and speed adjustable 
  |  |
|   Printer  |    All printers compatible with windows 
  |  |
|   Plate Incubation  |    AT+4 to 45°C, adjustable 
  |  |
|   Applications  |    ABS, cut-off, single standard, curve, multi-percent, percent log, linear, exponential, power, 4PL regression 
  |  |
|   Storage  |    More than 500 programs, up to 100,000 test result 
  |  |
|   Interface  |    
 RS-232  |  |
|   Dimensions  |    186x440x220 mm 
  |  |
|   Weight  |    9 Kg 
  |  |
|   Electrical Requirement  |    AC 110V/50 Hz, ±10%, 
  |    240V/60 ±1Hz  |  
|   Catalogue No.  |    420450501  |    420450502  |