Microplate Reader IMR-8000 provides benefit of a wider range of detection with 8-channel manifolds as standard accessories for use with standard 96 wells plates. Covers the full UV wavelength340 nm and absorbance range 0 to 4.000Abs with bandwidth <8 nm and measured quickly, which is significantly faster than other current microplate reader methods. End Point, fixed time, Kinetic make the IMR-8000 the best platform for any clinical, biotechnology research and pharmaceutical laboratory applications. Can stored more than 500 programs, up to 100,000test records in a single unit. Maintain all important measuring parameters including ABS, Cut-Off, Single Standard, Curve, Multi-Percent, Percent Log, Linear, Exponential, Power, and 4PL Regression. A multi-mode reader has several benefits for laboratories applications ranging from ELISAs to nucleic acid and protein quantitation to cell imaging. Together with multiple microplate services and detection modes into a single, more versatile unit may be an ideal choice especially if you have limited area and performed 12 assays in a single plate
Data sheet
Model | IMR-8000 | |
Wavelength | UV wavelength: 340 nm | |
Absorbance Range | 0 to 4000 Abs | |
Test Performance | 12 different | |
Optical Path | 8-channel | |
Wavelength Accuracy | ±1 nm | |
Resolution | 0.001 Abs (display), 0.0001 Abs (calculated)
| |
Light Source | Halogen lamp
| |
Band width | <8 nm | |
Optical filter | 340,405,450,492,630nm,(3 filters optional)
| |
Function | End point, fixed time, Kinetic
| |
Reading Speed | 5 Seconds for 96 well plate (single wavelength)
| |
Shaking | Shaking time and speed adjustable
| |
Printer | All printers compatible with windows
| |
Plate Incubation | AT+4 to 45°C, adjustable
| |
Applications | ABS, cut-off, single standard, curve, multi-percent, percent log, linear, exponential, power, 4PL regression
| |
Certification |
| |
Storage | More than 500 programs, up to 100,000 test result
| |
Interface |
RS-232 | |
Dimensions | 186x440x220 mm
| |
Weight | 9 Kg
| |
Electrical Requirement | AC 110V/50 Hz, ±10%,
| 240V/60 ±1Hz |
Catalogue No. | 420450501 | 420450502 |
| Model | IMR-8000 | |
| Wavelength | UV wavelength: 340 nm | |
| Absorbance Range | 0 to 4000 Abs | |
| Test Performance | 12 different | |
| Optical Path | 8-channel | |
| Wavelength Accuracy | ±1 nm | |
| Resolution | 0.001 Abs (display), 0.0001 Abs (calculated)
| |
| Light Source | Halogen lamp
| |
| Band width | <8 nm | |
| Optical filter | 340,405,450,492,630nm,(3 filters optional)
| |
| Function | End point, fixed time, Kinetic
| |
| Reading Speed | 5 Seconds for 96 well plate (single wavelength)
| |
| Shaking | Shaking time and speed adjustable
| |
| Printer | All printers compatible with windows
| |
| Plate Incubation | AT+4 to 45°C, adjustable
| |
| Applications | ABS, cut-off, single standard, curve, multi-percent, percent log, linear, exponential, power, 4PL regression
| |
| Storage | More than 500 programs, up to 100,000 test result
| |
| Interface |
RS-232 | |
| Dimensions | 186x440x220 mm
| |
| Weight | 9 Kg
| |
| Electrical Requirement | AC 110V/50 Hz, ±10%,
| 240V/60 ±1Hz |
| Catalogue No. | 420450501 | 420450502 |