Vertical Autoclave/Steam sterilizers IVA-4120
Vertical Autoclave/Steam sterilizers IVA-4120 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Touch Screen Horizontal Autoclave/Steam Sterilizer IHA-3180 basic 180L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
The IHA-3180 comes with PLC automatic microprocessor controller, LCD touch screen display. The benefits of product diversity and flexible options to make the right match and perfect fit for your customer needs The machine has maximum sterilization pressure of 105 and 138°C with overload pressure protection. Built-in micro-printer, record the whole sterilization information and alarm system. Built-in efficient steam generator, microcomputer temperature control, especially designed for bulk volume and highest flexibility in processing requirement
Data sheet
PLC fully automatic microprocessor controller, LCD touch screen display.
Water injection, heating up, sterilizing, drying process are fully automatic
Status, temperature, pressure, time and fault message are shown on touch screen display.
Built-in micro-printer, record the whole sterilization information.
Cycle count function
Perfect fault alarm system designed, fault messages shown on touch screen.
The beep will sound once the sterilization cycle completes and messages shown on screen touch display
Inner circulation, water ring pump without external pipeline
Model | IHA-3050 | IHA-3060 | IHA-3080 | IHA-3100 | IHA-3140 | IHA-3160 | IHA-3180 |
Capacity | 50L | 60L | 80L | 100L | 140L | 160L | 180L |
Chamber Size | 340×580 mm | 340×680 mm | 370×755 mm | 500×665 mm | 500×765 mm | 500×865 mm | 500×965 mm |
Materials | SUS304 | ||||||
Maximum Tem | 150? | ||||||
Maximum Pressure | 0.26MPa | ||||||
Operating Pressure | 0.23MPa | ||||||
Sterilization Tem | Adjustable 105 to 138? | ||||||
Temperature Accuracy | 0.1? | ||||||
Display | LCD | ||||||
Certification |
|
|
|
|
|
|
|
Power Consumption | 3000 W | 3000 W | 4000 W | 6700 W | 6700 W | 7100 W | 7100 W |
Dimension | 780×480×1450 | 780×480×1450 | 870×540×1450 | 780×650×1550 | 880×650×1550 | 910×650×1550 | 1080×650×1550 |
Net Weight | 150 kg | 165 kg | 185 kg | 247 kg | 270 kg | 285 kg | 310 kg |
Electrical Requirement | 220 V | 380 V | |||||
Catalogue No. | 580800502 | 580801002 | 580801502 | 580802002 | 580802502 | 580803002 | 580803502 |
| Model | IHA-3050 | IHA-3060 | IHA-3080 | IHA-3100 | IHA-3140 | IHA-3160 | IHA-3180 |
| Capacity | 50L | 60L | 80L | 100L | 140L | 160L | 180L |
| Chamber Size | 340×580 mm | 340×680 mm | 370×755 mm | 500×665 mm | 500×765 mm | 500×865 mm | 500×965 mm |
| Materials | SUS304 | ||||||
| Maximum Tem | 150? | ||||||
| Maximum Pressure | 0.26MPa | ||||||
| Operating Pressure | 0.23MPa | ||||||
| Sterilization Tem | Adjustable 105 to 138? | ||||||
| Temperature Accuracy | 0.1? | ||||||
| Display | LCD | ||||||
| Certification |
|
|
|
|
|
|
|
| Power Consumption | 3000 W | 3000 W | 4000 W | 6700 W | 6700 W | 7100 W | 7100 W |
| Dimension | 780×480×1450 | 780×480×1450 | 870×540×1450 | 780×650×1550 | 880×650×1550 | 910×650×1550 | 1080×650×1550 |
| Net Weight | 150 kg | 165 kg | 185 kg | 247 kg | 270 kg | 285 kg | 310 kg |
| Electrical Requirement | 220 V | 380 V | |||||
| Catalogue No. | 580800502 | 580801002 | 580801502 | 580802002 | 580802502 | 580803002 | 580803502 |
Vertical Autoclave/Steam sterilizers IVA-4120 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Vertical Autoclave/Steam sterilizers IVA-1200D are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Vertical Autoclave/Steam sterilizers IVA-1600 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Touch Screen Horizontal Autoclave/Steam Sterilizer IHA-3060 basic 50L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Vertical Autoclave/Steam sterilizers IVA-3100 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Vertical Autoclave/Steam sterilizers IVA-2400WC are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Vertical Autoclave/Steam sterilizers IVA-2200WC are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Vertical Autoclave/Steam sterilizers IVA-2200 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
The ITA-212 front loading ‘Benchtop’ autoclave range is available in four sizes. These units require no plumbing, and only a standard single phase power supply. A 5.7-inch colour touchscreen with integrated USB data port. Electro polished stainless steel chamber.
Digital Autoclave/Steam Sterilizer IHA-5200 basic 200 L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
The ITA-223 front loading ‘Benchtop’ autoclave range is available in four sizes. These units require no plumbing, and only a standard single phase power supply. A 5.7-inch colour touchscreen with integrated USB data port. Electro polished stainless steel chamber.
Steam Sterilisers/Autoclave ITA-840 provide the broadest range of steam sterilizers and has a solution available to maximize department productivity and optimize workflow.
Steam Sterilisers/Autoclave ITA-860 provide the broadest range of steam sterilizers and has a solution available to maximize department productivity and optimize workflow.
Vertical Autoclave/Steam sterilizers IVA-2600C are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
The ITA-424 front loading ‘Benchtop’ autoclave is pulse vacuum type and range is available in single sizes of 24 litres chamber capacity. These units require no plumbing, and only a standard single phase power supply. Build in 7 Sterilization cycles + 2 User definable cycles + 2 Test programs.
Vertical Autoclave/Steam sterilizers IVA-1800 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.