Gradient Thermal Cyclers ITCG-1310
Gradient Thermal Cyclers ITCG-1310 accommodates 96×0.2 ml + 77×0.5 ml, and this block are completely independently of each other and without interference.
Dual Block Thermal Cyclers ITCM-4020D accommodates 60×0.5 ml, this block is completely independently of each other and without interference Fabricated with anodizing technology that have prompt heating conducting and adequate corrosion resistance property.
Dual Block Thermal Cyclers ITCM-4020D has been used in PCR applications in research and development, food science, pharmaceuticals, life science, animal diagnostics, and analytical laboratories. Features with customized Marlow Peltier heating units and form 4 circuits to control 4 temperature zones with vibrant touch LCD display and maximum ramping rate 5 ℃/s.
Dual Block Thermal Cyclers ITCM-4020D accommodates 60×0.5 ml, this block is completely independently of each other and without interference Fabricated with anodizing technology that have prompt heating conducting and adequate corrosion resistance property.
Data sheet
| Model | ITCM-4005D | ITCM-4010D | ITCM-4015D | ITCM-4020D | ITCM-4025D | ITCM-4030D | ITCM-4035D | ITCM-4040D | ITCM-4045D | ITCM-4050D | ||||||
| Capacity | 96×0.2 ml | 60×0.5 ml | 2×48×0.2 ml | 48×0.2 ml + 30×0.5 ml | 384 well, In-situ Plate | |||||||||||
| Display | LCD, 8 inch, 800×600 pixels | |||||||||||||||
| Temperature Range | 0 to 100? | |||||||||||||||
| Number of Program | 10000 +(USB FLASH) | |||||||||||||||
| Uniformity | ? ± 0.2? | |||||||||||||||
| Accuracy | ? ± 0.1? | |||||||||||||||
| Resolution | 0.1? | |||||||||||||||
| Number of Cycle | 100 | |||||||||||||||
| Number of Step | 30 | |||||||||||||||
| Holding Temperature | 4? | |||||||||||||||
| Temperature Control | BlockTube | |||||||||||||||
| Heating Rate | 5?/s | |||||||||||||||
| Cooling Rate | 4?/s | |||||||||||||||
| Ramping Rate Adjustable | 0.1 to 5? | |||||||||||||||
| Gradient Temp. Range | - | 30 to 100? | - | 30 to 100? | - | 30 to 100? | - | 30 to 100? | - | 30 to 100? | ||||||
| Gradient Uniformity | - | ?±0.2? | - | ?±0.2? | - | ?±0.2? | - | ?±0.2? | - | ?±0.2? | ||||||
| Gradient Accuracy | - | ?±0.2? | - | ?±0.2? | - | ?±0.2? | - | ?±0.2? | - | ?±0.2? | ||||||
| Gradient Spread | - | 1 to 30? | - | 1 to 30? | - | 1 to 30? | - | 1 to 30? | - | 1 to 30? | ||||||
| Hot Lid Height Adjustable | Step less Adjustable | |||||||||||||||
| Hot Lid Temperature | 30 to 110? | |||||||||||||||
| Connectivity | USB 2.0, LAN | |||||||||||||||
| Temp Increment/Decrement | 0.1 to 10.0? | |||||||||||||||
| Increase/Decrease in Time | 1 Sec to 600 Sec | |||||||||||||||
| Power consumption | 600 W | |||||||||||||||
| Overall Dimensions | 390×270×255 mm | |||||||||||||||
| Net Weight | 9 kg | |||||||||||||||
| Electrical Requirements | 264 V AC , 47 to 63 Hz | |||||||||||||||
| Catalogue No. | 620300503 | 620301003 | 620301503 | 620302003 | 620302503 | 620303003 | 620303503 | 620304003 | 620304503 | 620305003 | ||||||
Gradient Thermal Cyclers ITCG-1310 accommodates 96×0.2 ml + 77×0.5 ml, and this block are completely independently of each other and without interference.
Gradient Thermal Cyclers ITCG-1510 accommodates 54×0.5 ml, and this block are completely independently of each other and without interference.
The Iris Advanced Thermal Cyclers ITCP-5300 is designed with 3 different gradient system including nonlinear gradient, dynamics gradient, and 2D gradient. Suitable for the denaturation, enzymes cutting, enzymes link and ELISA assay applications. Offer high heating and cooling rate with the Peltier design unit. Equipped with 11 standard programs for fast editing in particular programs.
The Iris ITR-1010 real time PCR is applicable for real-time detection in farming, breeding, pasteurization, and water sources along with other useful application for detecting and diagnosis epidemic disease, inspection and quarantine in the field of food safety and R & D sectors
The Iris Advanced Thermal Cyclers ITCP-5200 is designed with 3 different gradient system including nonlinear gradient, dynamics gradient, and 2D gradient. Suitable for the denaturation, enzymes cutting, enzymes link and ELISA assay applications. Offer high heating and cooling rate with the Peltier design unit. Equipped with 11 standard programs for fast editing in particular programs.
qLab Thermal Cyclers ITCL-1200 accommodates 96×0.2 ml +77×0.5 ml, and this block are completely independently of each other and without interference. Fabricated with anodizing technology that has prompt heating conducting and adequate corrosion resistance property.
qLab Thermal Cyclers ITCL-1300 accommodates 60×0.5 ml, and this block are completely independently of each other and without interference. Fabricated with anodizing technology that has prompt heating conducting and adequate corrosion resistance property.
Real-Time PCR System 6 Channel ITR-6000 has been used in immunology, HGP, forensic medicine, oncology, histology, population biology, paleobiologic, zoology, botany and clinical diagnosis of viruses, tumours and hereditary disorder.
Dual Block Thermal Cyclers ITCM-4035D accommodates 48×0.2 ml + 30×0.5 ml, this block is completely independently of each other and without interference Fabricated with anodizing technology that have prompt heating conducting and adequate corrosion resistance property.
Real-Time PCR System 6 Channel ITR-6000 has been used in immunology, HGP, forensic medicine, oncology, histology, population biology, paleobiologic, zoology, botany and clinical diagnosis of viruses, tumours and hereditary disorder.
Real-Time PCR System 2 Channel ITR-2000 has been used in immunology, HGP, forensic medicine, oncology, histology, population biology, paleobiologic, zoology, botany and clinical diagnosis of viruses, tumours and hereditary disorder.
Dual Block Thermal Cyclers ITCM-4040D accommodates 48×0.2 ml + 30×0.5 ml, this block is completely independently of each other and without interference Fabricated with anodizing technology that have prompt heating conducting and adequate corrosion resistance property.
qGene Thermal Cyclers ITCL-2080 has been used in PCR applications in research and development, food science, pharmaceuticals, life science, animal diagnostics, and analytical laboratories.
The Iris Advanced Thermal Cyclers ITCP-5100 is designed with 3 different gradient system including nonlinear gradient, dynamics gradient, and 2D gradient. Suitable for the denaturation, enzymes cutting, enzymes link and ELISA assay applications. Offer high heating and cooling rate with the Peltier design unit. Equipped with 11 standard programs for fast editing in particular programs.
qLab Thermal Cyclers ITCL-1400 accommodates 384 well, and this block are completely independently of each other and without interference. Fabricated with anodizing technology that has prompt heating conducting and adequate corrosion resistance property.
Advanced Thermal Cyclers ITCP-6000 has been used in rapid outdoor detection, all kinds of isothermal amplification of DNA/RNA. Mainly used in Gene amplification with the highest flexibility.