The FHP-1800 Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
The FHP-1800 Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
LCD Display

Waterproof Socket

PP sink
Resistant strong acid, alkali and anti-corrosion

Water & Gas Remote Control Valve

Data sheet
Model | FHP-1300 | FHP-1500 | FHP-1600 | FHP-1800 | |||||
External Size (W*D*H) mm | 1040*750*2200mm | 1240*800*2200mm | 1540*800*2200mm | 1840*800*2200 mm | |||||
Internal Size (W*D*H) mm | 820*520*872mm | 1020*570*872mm | 1320*570*872mm | 1620*570*872 mm | |||||
Capacity (liters) | 371 | 506 | 656 | 805 | |||||
Work Surface Height | 700mm | ||||||||
Max Opening | 815mm | ||||||||
Air Velocity | 0.4~0.6m/s | ||||||||
Noise | ?60dB | ||||||||
Fluorescent Lamp | 12W*1 | 30W*2 | 30W*2 | 30W*2 | |||||
Blower | Built-in axial flow blower; Speed adjustable. | ||||||||
Front Window | Manual, 5mm toughened glass, height adjustable . | ||||||||
Power Supply | AC220V±10%, 50/60Hz ; 110V±10%, 60Hz | ||||||||
Consumption | 330W | 360W | 360W | 360W | |||||
Material | Main Body | Made of Porcelain white PP, thickness 8mm, resistant to strong acid, alkali and anti-corrosion | |||||||
Work Table | Chemical resistant phenolic resin | ||||||||
Standard Accessory | Fluorescent lamp, Water tap, Gas tap, Water Sink, Base cabinet | ||||||||
Waterproof socket*2 | |||||||||
4 meter PVC duct, Diameter:250mm | |||||||||
Optional Accessory | PP work table, epoxy resin board or ceramic board. | ||||||||
Outer centrifugal blower, resistant to strong acid, alkali. | |||||||||
Gross Weight | 160kg | 198kg | 225kg | 259kg | |||||
Package Size | Main Body | 1110*835*1575 mm | 1310*885*1575 mm | 1610*885*1575 mm | 1910*885*1575 mm | ||||
Base Cabinet | 1110*790*950 mm | 1310*840*950 mm | 1610*840*950 mm | 1910*840*1575 mm | |||||
Electrical Requirement | 110V | 220V | 110V | 220V | 110V | 220V | 110V | 220V | |
Catalogue No. |
|
|
|
|
|
|
|
| |
| Model | FHP-1300 | FHP-1500 | FHP-1600 | FHP-1800 | |||||
| External Size (W*D*H) | 1040*750*2200mm | 1240*800*2200mm | 1540*800*2200mm | 1840*800*2200 mm | |||||
| Internal Size (W*D*H) | 820*520*872mm | 1020*570*872mm | 1320*570*872mm | 1620*570*872 mm | |||||
| Capacity (liters) | 371 | 506 | 656 | 805 | |||||
| Work Surface Height | 700mm | ||||||||
| Max Opening | 815mm | ||||||||
| Air Velocity | 0.4~0.6m/s | ||||||||
| Noise | ?60dB | ||||||||
| Fluorescent Lamp | 12W*1 | 30W*2 | 30W*2 | 30W*2 | |||||
| Blower | Built-in axial flow blower; Speed adjustable. | ||||||||
| Front Window | Manual, 5mm toughened glass, height adjustable . | ||||||||
| Power Supply | AC220V±10%, 50/60Hz ; 110V±10%, 60Hz | ||||||||
| Consumption | 330W | 360W | 360W | 360W | |||||
| Material | Main Body | Made of Porcelain white PP, thickness 8mm, resistant to strong acid, alkali and anti-corrosion | |||||||
| Work Table | Chemical resistant phenolic resin | ||||||||
| Standard Accessory | Fluorescent lamp, Water tap, Gas tap, Water Sink, Base cabinet | ||||||||
| Waterproof socket*2 | |||||||||
| 4 meter PVC duct, Diameter:250mm | |||||||||
| Optional Accessory | PP work table, epoxy resin board or ceramic board. | ||||||||
| Outer centrifugal blower, resistant to strong acid, alkali. | |||||||||
| Gross Weight | 160kg | 198kg | 225kg | 259kg | |||||
| Package Size | Main Body | 1110*835*1575 mm | 1310*885*1575 mm | 1610*885*1575 mm | 1910*885*1575 mm | ||||
| Base Cabinet | 1110*790*950 mm | 1310*840*950 mm | 1610*840*950 mm | 1910*840*1575 mm | |||||
| Electrical Requirement | 110V | 220V | 110V | 220V | 110V | 220V | 110V | 220V | |
| Catalogue No. |
|
|
|
|
|
|
|
| |
| Model | Image | Name | Product Detail | Availability | Price | Action |
|
Water & Gas Tap, Water Sink for Fume Hoods |
Water & Gas Tap, Water Sink |
Price On Request |
|
||
|
Foot switch for Fume Hoods |
Use foot switch to adjust the height of front window |
Price On Request |
|
||
|
Observation Window for Fume Hoods |
Transparent side glass windows maximize light and visibility inside the cabinet |
Price On Request |
|
||
|
Back Side Air Compensation for Fume Hoods |
Back Side Air Compensation: To avoid turbulence in work area |
Price On Request |
|
||
|
Water & Gas Remote Control for Fume Hoods |
Water & Gas Remote Control |
Price On Request |
|
||
|
Water Sink for Fume Hoods |
Water Sink |
Price On Request |
|
||
|
Waterproof Socket for Fume Hoods |
Waterproof Socket |
Price On Request |
|
||
|
UV Lamp for Fume Hoods |
UV Lamp |
Price On Request |
|
||
|
PP Sink for Fume Hoods |
PP sink |
Price On Request |
|
Transparent side glass windows maximize light and visibility inside the cabinet
Back Side Air Compensation: To avoid turbulence in work area
Fume Hood FHS-1900 is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Fume Hood FHD-1400 is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Fume Hood FHS-1500 is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
The FHP-1600 Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Fume Hood FHD-1500 is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
The FHT-1500 Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapors and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Fume Hood FHW-1200 is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
The FHT-1800 Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapors and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Fume Hood FHS-1400 is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Fume Hood FHD-1700 is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
The FHP-1500 Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Fume Hood FHS-1700 is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
The FHP-1300 Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Fume Hood FHW-1500 is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapours and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
The FHT-1600 Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapors and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.