Single Door Horizontal Autoclave/Steam Sterilizer IHA-8200S(230V)
Single Door Horizontal Autoclave/Steam Sterilizer IHA-8200S basic 250L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Single Door Horizontal Autoclave/Steam Sterilizer IHA-8200S basic 250L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
The IHA-8200S comes with steam source including saturated steam of 97% Dryness, pressure: 3.50 to 5.00bar, and water source pressure: 2.10 to 5 bar. The machine has maximum sterilization pressure of 121 to 134°C with overload pressure protection. Built-in efficient steam generator, microcomputer temperature control, especially designed for bulk volume and highest flexibility in processing requirement.
Data sheet
Ergonomic Design for Maximizing Operator's Safety and Convenience
Cycle Program and Self-Diagnosis Function
Cycle Execution Data Storing and Ubiquitous Function
Model | IHA-8200S | IHA-8200D | ||
Type | Single Door type | Double Door type | ||
Capacity | 250L | |||
Chamber Size | 500x000x500 mm | |||
Materials | 316L | |||
Working Temperature | 121 to 135.0? | |||
Air Removal | Vacuum / Gravity | |||
Stream Source | Saturated Steam of 97% Dryness, Pressure: 3.50 to 5.00bar, Flow Rate: max. 50?/hr | |||
Water Source | Pressure: 2.10 to 5.00bar, Flow Rate: max. 50 l/min | |||
Vacuum System | Water Ejector, Water Pump / Optional: Watering Vacuum Pump | |||
Display | LCD | |||
Controller | Microprocessor | |||
Certification |
|
| ||
Working Temperature | +5? to +40? | |||
Humidity | 80% | |||
Printer | Direct Thermal Printing, Printing Paper Roll; 58 x 40mm | |||
Power Consumption |
|
| ||
Dimension | 872x300x801 mm | 872x350x803 mm | ||
Net Weight | 710 ?, Loading Car: 28 ? | 860 ?, Loading Car: 28 ? | ||
Electrical Requirement (In case of using Built-in Steam Generator) | AC 230V, 3phase 3wire, 50/60?, 55A or AC 380V, 3phase 4wire, 50/60?, 32A |
| ||
Electrical Requirement(In case of using External Steam) | AC 230V, 50/60?, 5A | AC 380V, 3phase 4wire, 50/60?, 32A | AC 230V, 50/60?, 5A | AC 380V, 3phase 4wire, 50/60?, 32A |
Catalogue No. | 5801050502 | 5801050503 | 5801051002 | 5801051003 |
|
Model | IHA-8200S | IHA-8200D | ||
| Type | Single Door type | Double Door type | ||
| Capacity | 250L | |||
| Chamber Size | 500x000x500 mm | |||
| Materials | 316L | |||
| Working Temperature | 121 to 135.0? | |||
| Air Removal | Vacuum / Gravity | |||
| Stream Source | Saturated Steam of 97% Dryness, Pressure: 3.50 to 5.00bar, Flow Rate: max. 50?/hr | |||
| Water Source | Pressure: 2.10 to 5.00bar, Flow Rate: max. 50 l/min | |||
| Vacuum System | Water Ejector, Water Pump / Optional: Watering Vacuum Pump | |||
| Display | LCD | |||
| Controller | Microprocessor | |||
| Certification |
|
| ||
| Working Temperature | +5? to +40? | |||
| Humidity | 80% | |||
| Printer | Direct Thermal Printing, Printing Paper Roll; 58 x 40mm | |||
| Power Consumption |
|
| ||
| Dimension | 872x300x801 mm | 872x350x803 mm | ||
| Net Weight | 710 ?, Loading Car: 28 ? | 860 ?, Loading Car: 28 ? | ||
| Electrical Requirement (In case of using Built-in Steam Generator) | AC 230V, 3phase 3wire, 50/60?, 55A or
AC 380V, 3phase 4wire, 50/60?, 32A |
| ||
| Electrical Requirement(In case of using External Steam) | AC 230V, 50/60?, 5A | AC 380V, 3phase 4wire, 50/60?, 32A | AC 230V, 50/60?, 5A | AC 380V, 3phase 4wire, 50/60?, 32A |
| Catalogue No. | 5801050502 | 5801050503 | 5801051002 | 5801051003 |
Single Door Horizontal Autoclave/Steam Sterilizer IHA-8200S basic 250L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Double Door Horizontal Autoclave/Steam Sterilizer IHA-8200D basic 250L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Horizontal Autoclave/Steam Sterilizer IHA-2600 basic 280 L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Benchtop Autoclave/Steam Sterilisers ITA-745 provide the broadest range of steam sterilizers and has a solution available to maximize department productivity and optimize workflow. It can be used to Inactivated AIDS (HV), hepatitis B (HBV) mad cow virus and spores.
Pulse Vacuum Large Horizontal Autoclave/Steam Sterilizer IHA-6300 basic 600L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Touch Screen Horizontal Autoclave/Steam Sterilizer IHA-3140 basic 140L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Vertical Autoclave/Steam sterilizers IVA-2400C are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Touch Screen Horizontal Autoclave/Steam Sterilizer IHA-3100 basic 100L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Vertical Autoclave/Steam sterilizers IVA-2200WC are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Touch Screen Horizontal Autoclave/Steam Sterilizer IHA-3050 basic 50L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Vertical Autoclave/Steam sterilizers IVA-4075 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Vertical Autoclave/Steam sterilizers IVA-1600D are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Touch Screen Horizontal Autoclave/Steam Sterilizer IHA-3160 basic 160L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Vertical Autoclave/Steam sterilizers IVA-2600WC are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
The ITA-212 front loading ‘Benchtop’ autoclave range is available in four sizes. These units require no plumbing, and only a standard single phase power supply. A 5.7-inch colour touchscreen with integrated USB data port. Electro polished stainless steel chamber.
Vertical Autoclave/Steam sterilizers IVA-1400 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.