Syringe Filters

Iris Syringe Filters are used for small volume filtration of liquids, gas and other material-specific applications. They are made of extractable free virgin polypropylene housings with female luer lock and male luer slip fittings.

New sealing ring design makes itself for high operating pressure and faster filtration. They are produced to ex...

download pdf product details
  • Full Description
  • Specifications

Iris Syringe Filters are used for small volume filtration of liquids, gas and other material-specific applications. They are made of extractable free virgin polypropylene housings with female luer lock and male luer slip fittings.

New sealing ring design makes itself for high operating pressure and faster filtration. They are produced to exceptional quality standards and eliminate common problems such as leaks and filter ‘blow off’. Colour ring help identify membrane type inside easily.These syringe filters are ideal for applications in pharmaceutical, environmental, biotechnology, food, beverage and agricultural testing laboratories, used in industries like bioscience, pharmacy, microelectronics, chemistry, food & beverage, etc.

Iris Syringe Filters are available in the material of Nylon, MCE, CA, CN, PES, PVDF, PTFE, PP, Glass Fiber, with pore size ranging from 0.1pm to 10pm

Iris Syringe Filters are syringe-operated filters for the clarification of queous solutions (column elutes, tissue culture additives, HPLC samples, etc.). It is further to do the beautification appearance on general syringe filters basis and containing high quality membrane materials to make your experiment performance more perfect. Its design of colour coding, make the products more beautiful and innovative. The classic range is available in all of the major membranes including Nylon, PTFE, PVDF, CA and PES, which are supplied in 13mm, 25mm, 30mm formats in polypropylene housings.

  • Easy to identify- the colour coded band on housing clearly indicates the membrane material
  • Pressure rated - to 90psi for unsurpassed integrity
  • Sealing ring - minimizes bursting and leakage
  • Pore size of filter media are available from 0.22um, 0.45um
  • Universal luer lock/luer slip design for versatility and maximum operational safety
  • Chemically resistant - polypropylene housing
  • Maximum filtration area - ensure uniformity and speed due to sample distribution rings
  • Low extractable levels - generate interference free date
  • Unequivocal reproducibility across all filters and lots
  • Colour coding: Easier to tell the filter membrane
  • Better membrane media: Improved membrane flow rates
  • Application Compatibility: Broad range of filtration media meets diverse application needs and best for chromatography application
  • Sterile: Filters can be purchased pre-sterilized by Gamma radiation and individually packaged

 

Validated HPLC Performance

  • HPLC certification which guarantees the filters will not produce extraneous peaks in the UV range.
  • 100% integrity tested with higher burst strength ratings assuring they will perform consistently.
  • Available in 13 and 25mm sizes and available in sterile, too.
  • 0.45pm for most clarification applications and 0.22pm when fine particulate removal is required. Other pore size are available in 0.8 pm to 5pm.

 

Application

  •          HPLC sample preparation
  •          Routine QC analysis
  •          Content uniformity
  •          Removal of protein precipitate
  •          Dissolution testing
  •          Food analysis
  •          Bioscience analysis
  •          Environmental samples

Type

Nylon/PTFE/PES/PVDF/PTFEL/PVDF L

Diameter

13mm

25mm

30mm

Pore Size

0.22um, 0.45um

Effective Filtration Area(cm2)

1.09

4.08

5.39

Maximum Pressure

87psi (6.0 bar) at 20 ° C

87psi (6.0 bar) at 20 ° C

87psi (6.0 bar) at 20 ° C

Maximum Operating Temp.

50° C

50° C

50° C

Materials of Construction

Housing: Polypropylene

Housing: Polypropylene

Housing: Polypropylene

Filtration Media

As specified

Holdup volume (p 1)

<25

<100

<200

Sample volume (ml)

<10

<100

<200

Connectors

Inlet: Female Luer Lock

Outlet: Male Slip Luer

Inlet: Female Luer Lock

Outlet: Male Slip Luer

Inlet: Female Luer Lock

Outlet: Male Slip Luer

Flow Direction

Inlet: Female Luer Lock

Outlet: Male Slip Luer

Inlet: Female Luer Lock

Outlet: Male Slip Luer

Inlet: Female Luer Lock

Outlet: Male Slip Luer

Sterilisation

Autoclave at 121? at 1 bar for 20 minutes/EO/Gamma

  • Show Sidebar

There are 6 products.

Active filters

Nylon Syringe Filters
  • On sale!

Nylon Syringe Filters

$108.00

Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters
  • On sale!

Nylon Syringe Filters

$108.00

Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters Pore...
  • On sale!

Nylon Syringe Filters Pore Size 0.22 13mm

$77.50

Iris Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters Pore...
  • On sale!

Nylon Syringe Filters Pore Size 0.22 25mm

$97.50

Iris Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters Pore...
  • On sale!

Nylon Syringe Filters Pore Size 0.45 13mm

$77.50

Iris Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters Pore...
  • On sale!

Nylon Syringe Filters Pore Size 0.22μm, Ø 13mm

$90.00

Iris Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters
  • On sale!

Nylon Syringe Filters

$108.00

Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters
  • On sale!

Nylon Syringe Filters

$108.00

Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters Pore...
  • On sale!

Nylon Syringe Filters Pore Size 0.22 13mm

$77.50

Iris Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters Pore...
  • On sale!

Nylon Syringe Filters Pore Size 0.22 25mm

$97.50

Iris Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters Pore...
  • On sale!

Nylon Syringe Filters Pore Size 0.45 13mm

$77.50

Iris Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.

Nylon Syringe Filters Pore...
  • On sale!

Nylon Syringe Filters Pore Size 0.22μm, Ø 13mm

$90.00

Iris Hydrophilic Nylon membranes are suitable for filtering aqueous solutions and most organic solvents. It is ideal for HPLC, GC or dissolution sample analysis and widely used in most biological preparations, Electric semiconductor, industrial water filtration, chemicals filtration, drinks filtration.